Dark Light
,

Tripplite Inverter APSINT 2424


699.00 

The APSINT2424 2400W APS INT Series 24V DC 230V AC Inverter/Charger is a reliable power source
for a wide variety of equipment ranging from power tools and pumps to portable lighting and computer
equipment in heavy-load conditions. With no fumes, fuel or excess noise, it’s an excellent alternative to
generator power.
The DC-to-AC inverter features an automatic line-to-battery transfer switch and integrated charging
system that allow it to work as a vehicle inverter, standalone AC power source or extended-run UPS. It
delivers 2400W of continuous power, 3600W up to one hour, or 4800W of peak power up to 10 seconds
during equipment startup or cycling. An automatic overload detector, cooling fan and resettable AC circuit
breakers protect the unit from damage.
Designed for easy installation in RVs, commercial and fleet vehicles, emergency vehicles and construction
equipment, the APSINT2424 converts stored power from any 24V battery or automotive DC source to
safe, stable, computer-grade AC power for unlimited runtime. When hardwired to an external 230V AC
source, the unit keeps the user-supplied battery charged via a three-stage 30A charging system while
simultaneously delivering AC power to connected equipment.
When used as a UPS, the APSINT2424 responds to blackouts and brownouts with an automatic,
instantaneous transfer to battery-derived AC output. LEDs on the unit indicate AC/DC operational modes,
overload status, DC voltage level, shutdown status and system fault status.

SKU: 9546 Categories: ,
 

OVERVIEW

UPC Code 037332090324
 

INPUT

Nominal Input Voltage(s) Supported 230V AC
Maximum Input Amps / Watts DC INPUT: Full continuous load – 112A at 24VDC. AC INPUT: 17 amps at 230VAC with full inverter and charger load (7A max charger-only / combined input load to support charger and AC output is automatically controllable to 66%-33%-0% based on AC output loading using the charger limiting set points – see manual for setting instructions)
Recommended Electrical Service DC INPUT: Requires 24VDC input source capable of delivering 112A for the required duration (when used at full continuous capacity – DC requirements increase during OverPower and DoubleBoost operation). For automotive applications, professional hardwire installation with 300A minimum battery system fusing is recommended.
Input Connection Type DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: Hardwire via built in junction box with cover plate
Voltage Compatibility (VAC) 230

 

 

 

 

Voltage Compatibility (VDC) 24
 

OUTPUT

Frequency Compatibility 50 Hz
Pure Sine Wave Output No
Nominal Output Voltage(s) Supported  

230V

Output Receptacles Hardwire
Continuous Output Capacity (Watts) 2400
Peak Output Capacity (Watts) 4800
Output Voltage Regulation LINE POWER (AC): Maintains 230V nominal sine wave output from line power source. INVERTER POWER (AC): Maintains PWM sine wave output voltage of 230 VAC (+/-5%).
Output Frequency Regulation 50 Hz (+/- 0.3 Hz)
Overload Protection Includes 10A input breaker dedicated to the charging system and 15A output breaker for AC output loads.
 

BATTERY

Expandable Runtime Yes
Expandable Battery Runtime Runtime is expandable with any number of user supplied wet or gel type batteries
Expandable Runtime Description Runtime is expandable with any number of user supplied wet or gel type batteries
DC System Voltage (VDC) 24
Battery Pack Accessory (Optional)  98-121  sealed lead acid battery (optional)
Battery Charge 30A
 

USER INTERFACE, ALERTS & CONTROLS

Front Panel LEDs Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences.
Switches 3 position on/off/remote switch enables simple on/off power control plus “auto/remote” setting that enables distant on/off control of the inverter system when used in conjunction with optional  APSRM4  accessory when used in inverter mode. In AC uninterruptible power mode, “auto/remote” setting enables automatic transfer from line power to battery power – to maintain continuous AC power to connected loads.
 

PHYSICAL

Material of Construction Polycarbonate
Cooling Method Multi-speed fan
Form Factors Supported Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting information)
Shipping Dimensions (hwd / in.) 12.70 x 14.70 x 20.90
Shipping Dimensions (hwd / cm) 32.26 x 37.34 x 53.09
Shipping Weight (lbs.) 45.60
Shipping Weight (kg) 20.68

 

 

 

 

Unit Dimensions (hwd / in.) 7.250 x 8.500 x 16.250
Unit Dimensions (hwd / cm) 18.42 x 21.59 x 41.28
Unit Weight (lbs.) 38.2
Unit Weight (kg) 17.33
 

ENVIRONMENTAL

Relative Humidity 0%-95% Non-Condensing
 

LINE / BATTERY TRANSFER

Transfer Time (Line Power to Battery Mode) 20 milliseconds (typical – compatible with many computers, servers and networking equipment – verify transfer time compatibility of loads for UPS applications)
Low Voltage Transfer to Battery Power In AC “auto” mode, inverter/charger switches to battery mode as line voltage drops to 144V (user adjustable to 163, 182, 201V – see manual)
High Voltage Transfer to Battery Power In AC “auto” mode, inverter/charger switches to battery mode as line voltage increases to 259V (user adjustable to 264 – see manual)
 

FEATURES & SPECIFICATIONS

Load Sensing Optional load sense function enables automatic inverter shutoff and startup as connected equipment is powered off and on. Front panel load sense potentiometer can be set to shutoff or turn on inverter power in response to loads of any level, up to 150 watts.
 

STANDARDS & COMPLIANCE

Product Compliance RoHS