Dark Light
,

Tripplite Inverter APSX 6048 VRNET


The APSX6048VRNET 6000W APS X Series 48V DC 208/230V AC Inverter/Charger is a reliable power
source for a wide variety of power tools, computers, audio/video components and other sensitive
electronics at mobile, emergency and remote sites. With no fumes, fuel or excess noise, it’s an excellent
alternative to generator power.
The DC-to-AC pure sine-wave inverter delivers clean power to sensitive electronics. Its automatic line-tobattery transfer switch and integrated charging system allow the unit to work as a vehicle inverter,
standalone AC power source or extended-run UPS. It delivers 6000W of continuous power, 9000W up to
one minute or 12000W of peak power up to 10 seconds during equipment startup or cycling. An automatic
overload detector, cooling fan and resettable AC circuit breakers protect the unit from damage.
Designed for easy installation in RVs, commercial and fleet vehicles, emergency vehicles and construction
equipment, the APSX6048VRNET converts stored power from a 48V battery or automotive DC source to
safe, stable, computer-grade AC power for unlimited runtime in heavy-load conditions. When hardwired to
an external 208V or 230V AC source, the unit keeps the user-supplied battery charged via a three-stage
23/90A selectable charging system while simultaneously delivering conditioned, pure sine-wave AC power
to connected equipment.
When used as a UPS, the APSX6048VRNET responds to blackouts and brownouts with an automatic,
instantaneous transfer to battery-derived, pure sine-wave AC power. The optional SNMPWEBSOLOHV
accessory card enables remote monitoring of the unit via SNMP, SSH, Telnet, and Internet.

Kodi i produktit : 9548 Kategori: ,
 

OVERVIEW

UPC Code 037332137838
 

INPUT

Nominal Input Voltage(s) Supported 208V AC; 230V AC
Recommended Electrical Service DC INPUT: Requires 48VDC input source capable of delivering 138A for the required duration (when used at full continuous capacity – DC requirements increase during OverPower and DoubleBoost operation). For automotive applications, professional hardwire installation with 250A minimum battery system fusing is recommended.
Input Connection Type DC INPUT: Set of DC bolt-down terminals. AC INPUT: Hardwire via built in terminal strip with cover plate
Voltage Compatibility (VAC) 208; 230

 

 

 

 

Voltage Compatibility (VDC) 48
 

OUTPUT

Frequency Compatibility 50 / 60 Hz
Pure Sine Wave Output Yes
Nominal Output Voltage(s) Supported  

208V; 230V

Output Receptacles Hardwire
Continuous Output Capacity (Watts) 6000
Peak Output Capacity (Watts) 12000
Output Voltage Regulation LINE POWER (AC): Maintains 208/230V nominal sine wave output from line power source. INVERTER POWER (AC): Maintains sine wave output voltage of 208/230 VAC (+/-5%).
Output Frequency Regulation 50/60 Hz (+/- 0.3 Hz)
 

BATTERY

Expandable Runtime Yes
Expandable Battery Runtime Runtime is expandable with any number of user supplied wet or gel type batteries
Expandable Runtime Description Runtime is expandable with any number of user supplied wet or gel type batteries
DC System Voltage (VDC) 48
Battery Pack Accessory (Optional) &nbsp;<a class=”productLink” href=”//tripplite.eaton.com/12VDC-Sealed-Maintenance-Free-Battery-All-Inverter- Chargers-12VDC-Battery-Connections~98-121″>98-121</a>&nbsp; sealed lead acid battery (optional)
Battery Charge Selectable 23 / 90A
 

VOLTAGE REGULATION

Voltage Regulation Description Includes automatic voltage regulation to correct brownouts and over-voltages back to usable levels
Overvoltage Correction Input voltages above 252V are automatically reduced by 9% (230V) / Input voltages above 235/245V are automatically reduced by 10% (208V)
Brownout Correction Input voltages from 208V -189V are automatically boosted by 11% (230V) / Input voltages from 188V-166V are automatically boosted 12% (208V)
Severe Brownout Correction Input voltages from 188V – 171V are automatically boosted by 26% (230V only)
 

USER INTERFACE, ALERTS & CONTROLS

Front Panel LEDs Set of 6 LEDs offer continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences.
Switches 3 position on/off/remote switch enables simple on/off power control plus “auto/remote” setting that enables distant on/off control of the inverter system when used in conjunction with optional &nbsp;<a class=”productLink” href=”//tripplite.eaton.com/Remote-Control-Module-Tripp-Lite-PowerVerter-Inverters-Inverter- Chargers~APSRM4″>APSRM4</a>&nbsp; accessory when used in inverter mode. In AC uninterruptible power mode, “auto/remote” setting enables automatic transfer from line power to battery power – to maintain continuous AC power to connected loads.
 

PHYSICAL

Material of Construction Metal
Cooling Method Dual multi-speed fans

 

 

 

 

Form Factors Supported Mounting slots enable permanent placement of inverter on any horizontal surface (see manual for additional mounting information)
Shipping Dimensions (hwd / in.) 16.00 x 14.50 x 23.25
Shipping Dimensions (hwd / cm) 40.64 x 36.83 x 59.06
Shipping Weight (lbs.) 131.00
Shipping Weight (kg) 59.42
Unit Dimensions (hwd / in.) 10.080 x 8.960 x 19.450
Unit Dimensions (hwd / cm) 25.5 x 49.5 x 22.71
Unit Weight (lbs.) 106.50
Unit Weight (kg) 48.31
 

ENVIRONMENTAL

Relative Humidity 0%-95% Non-Condensing
 

COMMUNICATIONS

SNMP Compatibility Optional &nbsp;<a class=”productLink” href=”//tripplite.eaton.com/Power-Management-Tools-External-SNMP- Webcard-Module~SNMPWEBSOLOHV”>SNMPWEBSOLOHV</a>&nbsp; accessory card enables remote monitoring of the unit via SNMP, SSH, telnet or Internet.
Communications Interface Contact closure; DB9 Serial
 

LINE / BATTERY TRANSFER

Transfer Time (Line Power to Battery Mode) Dip-switch selectable 20 millisecond (full cycle) / 10 millisecond (half-cycle) transfer times which are compatible with many computers, servers and networking equipment – verify transfer time compatibility of loads for UPS applications
Low Voltage Transfer to Battery Power In 230V AC “auto” mode, inverter/charger switches to battery mode as line voltage drops to 170V AC (user adjustable to 180V). In 208V AC “auto” mode, inverter/charger switches to battery mode as line voltage drops to 165V (user adjustable to 175V)-see manual
High Voltage Transfer to Battery Power In 230V AC “auto” mode, inverter/charger switches to battery mode as line voltage increases to 260V (user adjustable to 270 – see manual), In 208V AC “auto” mode, inverter/charger switches to battery mode as line voltage increases to 235V (user adjustable to 245V-see manual)
 

FEATURES & SPECIFICATIONS

Grounding Main grounding lug connects inverter/charger to earth or vehicle chassis ground
Generator Start Compatibility RJ-11 port connects to a generator with user-supplied cable to automatically cycle generator when battery level is low
Battery Temperature Sensor RJ-11 port connects to optional battery temperature sensor cable to regulate the charging system based on battery temperature
 

STANDARDS & COMPLIANCE

Product Certifications IEC/EN 62040
Product Compliance RoHS; CE (Europe)