Dark Light
, ,

Invertor Hibrid Solar Sun-12K-SG02LP1-EU-12kW


SUN-12K-SG02LP1-EU-AM3

  • Colorful touch LCD, IP65 protection degree
  • AC couple to retrofit existing solar system
  • Max. charging/discharging current of 250A
  • 6 time periods for battery charging/discharging
  • Support storing energy from diesel generator
  • Max. 16 pcs parallel for on-grid and off-grid
    operation; Support multiple batteries parallel
Model SUN-7.6K-SG02LP1-EU-AM2 SUN-8K-SG02LP1-EU-AM2 SUN-10K-SG02LP1-EU-AM3 SUN-12K-SG02LP1-EU-AM3
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max.Charging Current(A) 190 190 220 250
Max.Discharging Current(A) 190 190 220 250
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of battery input 1
PV String Input Data
Max. PV Access Power (W)
15200 16000 20000 24000
Max DC Input Power(W) 12160 12800 16000 19200
Max DC Input Voltage(V) 500
Start-up Voltage(V) 125
MPPT Voltage Range(V) 150-425
Rated DC Input Voltage(V) 370
Max. Operating PV Input Current (A) 26+26 26+26+26
Max. Input Short-Circuit Current (A) 44+44 44+44+44
No.of MPP Trackers/No.of String Per MPP Tracker 2/2+2 3/2+2+2
AC Input/Output Data
Rated AC Input/Output Active Power(W) 7600 8000 10000 12000
Max AC Input/Output Apparent Power (VA) 8360 8800 11000 13200
Peak Power (off-grid)(W) 2 times of rated power,10s
Rated AC Input/Output Current(A) 34.6/33.1 36.4/34.8 45.5/43.5 54.6/52.2
Max AC Input/Output Current(A) 34.6/33.1 36.4/34.8 45.5/43.5 54.6/52.2
Max Continuous AC Passthrough (grid to load)(A) 50 60
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5%ln
Efficiency
Max Efficiency 97.6%
Euro Efficiency 96.5%
MPPT Efficiency >99%
Equipment Protection
Integrated
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
Communication Interface RS485/RS232/CAN
Monitor Mode
GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range
-40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0~100%
Permissible Altitude 2000m
Noise <45
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC IV(AC)
Cabinet size(W*H*D)[mm] 420×670×233(Excluding connectors and brackets)
Weight[kg] 35.6
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of Cooling Intelligent air cooling
Grid Regulation VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1,
G98, G99, C10-11, UNE217002, NBR16149/NBR16150
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2