Inverter 12KW 48VDC MPPT 200A PV-145V


Inverter 12kW is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger to offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.

DATASHEET

2,600.00 

  • Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
  • Built-in MPPT solar charge controller 100A
  • MPPT efficiency max 98%
  • Powerful charge rate up to 80Amp
  • DC start &Automatic Self-Diagnostic Function
  • USB monitoring function
  • Supporting AGS, BTS port
  • Compatible to generator
    MODEL
    Nominal Battery System Voltage 48VDC
    INVERTER OUTPUT
    Rated power 12.0KW
    Surge rating 36000VA
    Capable of starting electric motor 6HP
    Waveform Pure sine wave / same as input (bypass mode)
    Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
    Output frequency 50Hz / 60Hz ± 0.3Hz
    Inverter effciency(peak) >88%
    Line mode efficiency >95%
    Power factor 1.0
    Typical transfer time 20ms(max)
    AC INPUT
    Voltage 220V/230V/240V
    Selectable voltage range 90-280 VAC (APL)
    Frequency range 50Hz / 60Hz
    BATTERY
    Low battery voltage cutoff 40-48VDC for 48VDC mode
    Low battery voltage recover 42-50VDC for 48VDC mode
    High battery voltage cutoff 60VDC for 48VDC mode
    High battery voltage recover 57VDC for 48VDC mode
    Idle consumption-search mode < 60W when power saver on
    AC CHARGER
    Output voltage Depends on battery type
    Charger AC input breaker rating 80A
    Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
    Maximum charge current 80A
    BTS
    Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
    BYPASS & PROTECTION
    Input voltage waveform Sine wave (grid or generator)
    Nominal input frequency 50Hz or 60Hz
    Overload protection (SMPS Load) Circuit breaker
    Output short circuit protection Circuit breaker
    Bypass breaker rating 63A 63A 63A
    Max bypass current 80Amp
    SOLAR CHARGER
    Maximum PV charge current 100A
    DC voltage 48V
    Maximim PV array power 5000W(10000W for 200A optional)
    MPPT range @ operating voltage(VDC) 64~145VDC
    Maximum PV array open circuit voltage 145VDC
    Maximum effciency >98%
    Standby power consumption <2W
    MECHANICAL SPECIFICATIONS
    Mounting Wall mount
    Dimensions (W*H*D) 670*410*215mm
    Net weight (solar CHG) (kg) 75.75 2.5
    Shipping dimensions (W*H*D) 884*618*443mm
    Shipping weight (Solar CHG) (kg) 92 2.5
    OTHER
    Operation temperature range 0°C to 40°C
    Storage temperature -15°C to 60°C
    Audible noise 60dB MAX
    Display LED LCD