Dark Light
,

FUJI FU-SUN-60K-G Inverter 60kW Three Phase


Higher yields / Safe & Reliable / Smart / User-friendly

DATASHEET
MANUAL

4,303.96 

The Fuji 60K grid-connected inverter is suited for medium and large-scale commercial rooftops and ground-mounted solar PV system in which reliability and stability are important. the full series inverter has 30% DC input oversizing ratio and 10% AC output overloading ratio, offering a faster return on investment.

  • 4 MPP tracker, Max. efficiency up to 98.7%
  • Zero export application, VSG application
  • String intelligent monitoring (optional)
  • Wide output voltage range
  • Type II DC/AC SPD
  • Anti-PID function (Optional)
SKU: 8690 Categories: ,
Model FU-SUN-60K-G FU-SUN-70K-G FU-SUN-75K-G FU-SUN-80K-G
Input Side
Max. DC Input Power(kW) 78 91 97.5 104
Max. DC Input Voltage (V) 1000
Start-up DC Input Voltage(V) 250
MPPT Operating Range(V) 200~850
Max. DC Input Current(A) 40+40+40+40
Max. Short Circuit Current (A) 60+60+60+60
Number of MPPT/Strings per MPPT 4/3 4/4 4/4 4/4
Output Side
Rated Output Power(kW) 60 70 75 80
Max. Active Power(kW) 66 77 82.5 88
Rated AC Grid Voltage(V) 230 / 400
AC Grid Voltage Range(V) 277Vac~460Vac(this may vary with grid standards)
Rated Grid Frequency(Hz) 50 / 60 (Optional)
Operating Phase Three phase
Rated AC Grid Output Current(A) 87 101.5 108.7 115.9
Max. AC Output Current(A) 95.7 111.6 119.6 127.5
Output Power Factor 0.8 leading to 0.8 lagging
Grid Current THD <3%
DC Injection Current(mA) <0.5%
Grid Frequency Range 47~52 or 57~62 (Optional)
Efficiency
Max.Efficiency 98.7%
Euro Efficiency 98.7%
MPPT Efficiency >99%
Protection
DC Reverse-Polarity Protection Yes
AC Short Circuit Protection Yes
AC Output Overcurrent Protection Yes
Output Overvoltage Protection Yes
Insulation Resistance Protection Yes
Ground Fault Monitoring Yes
Islanding Protection Yes
Temperature Protection Yes
Integrated DC Switch Yes
Remote software upload Yes
Remote change of operating parameters Yes
Surge protection DC Type II / AC Type II
General Data
Size(mm) 700W×575H×297D
Weight(kg) 60
Topology Transformerless
Internal Consumption <1W(Night)
Running Temperature -25~65℃, >45℃ derating
Ingress Protection IP65
Noise Emission(Typical) <55 dB
Cooling Concept Smart cooling
Max. Operating Altitude Without Derating 2000m
Designed Lifetime >20years
Grid Connection Standard           CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
Operating Surroundings Humidity 0-100%
Safety EMC/Standard       IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Features
DC Connection MC-4 mateable
AC Connection IP65 rated plug
Display LCD 240 × 160
Interface RS485/RS232/Wifi/LAN