G3 Starter Kit Pro (UA-G3-SK-PRO)
609.45 €
Starter kit that provides complete entry and exit control for a single door with two readers and Touch Pass support.
Koha e arritjes së produktit : Maj 27, 2026 - Maj 28, 2026
Kodi i produktit :
99621
Kategori: Door Access
Përshkrim
Ubiquiti G3 Starter Kit Pro – Technical Specifications
UA-Hub-Door
Mechanical
- Dimensions: 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3″)
- Weight: 363 g (12.8 oz)
- Enclosure material: Polycarbonate
- Mounting material: Polycarbonate
Hardware
- Networking interface: (5) 10/100/1000 Base-T
- Power method: PoE++, UL 294 Power-limited Class 2 PSU, UL 60950-1/62368-1 LPS/PS2 PSU
- Max. power consumption: Without PoE output: 30W, With PoE output: 50W
- PoE input: 50V DC, 1A
- PoE output: PoE passthrough, (4) PoE, 50V DC, total 20W
- LEDs: White/blue
- Button: (1) Factory-reset
- Digital input: Request to exit/request to enter/remote release/door position sensor
- Dry output relay: Lock: 30V DC, 1A, Aux: 30V DC, 1A
- Powered output relay: Lock: 12V DC, 1A, Aux: 12V DC, 0.33A, 12V DC, 0.33A
- Operating environment: Indoor use only
- Ambient operating temperature: 0 to 40° C (32 to 104° F)
- Ambient operating humidity: 5 to 95% noncondensing
- UL 294 level: Destructive attack: Level I, Line security: Level I, Endurance: Level I, Standby power: Level I
- UL 294 statement: Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
- CAN/ULC-60839-11-1 Grade: Grade assignment: 1
- Certifications: CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Wiring Information
-
- Wiring gauge requirements (AWG)
| Total length to device | Output load currnt at 12V DC | |||
| 100mA | 250mA | 500mA | 1A | |
| 6.1m (20 ft) | 22 | 22 | 22 | 18 |
| 15.2m (50ft) | 22 | 22 | 22 | 18 |
| 30.5m (100ft) | 22 | 22 | 18 | 18 |
UACC-Cable-DoorLockRelay (18 AWG) is recommended.
- PoE cabling requirements: The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
UA-G3-Pro
Mechanical
- Mechanical Dimensions: 160 x 40.4 x 40.55 mm (6.3 x 1.59 x 1.6″)
- Weight: 136 g (4.8 oz)
- Enclosure material: Polycarbonate, glass
- Mount material: Aluminum alloy
- Mounting: Wall mount (Included), Gangbox mount (Included), Angle mount (Optional), Junction box (Optional)
- Weatherproofing: IP55
Hardware
- Networking interface: (1) GbE RJ45 port
- Connectivity: BLE 4.2
- Power method: PoE UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU
- Supported voltage range: 48V DC
- Max. power consumption: 6W
- ESD/EMP protection: Air: ±15kV, contact: ±8kV
- Sensor: Proximity sensor
- Camera view angle: H: 96.67°, V: 123.15°, D: 153.11°
- Microphone: Yes
- Speaker (1) 4 ohm, 1.5W
- LEDs: R/G/B/W/Amber
- Button: (1) Factory-reset
- NFC frequency: 13.56 MHz
- NFC read range: < 30 mm
- NFC technology: ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340), MIFARE Classic / MIFARE DESFIRE, Sony FeliCa™ (ID only), NFC Forum tags T1T, T2T, T3T, T4T and T5T, ECP 2.0
- Operating environment: Outdoor use
- Ambient operating temperature: Device: -30 to 45° C (-22 to 113° F) Display:* -10 to 45° C (14 to 113° F) *The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v1.3.28)
- Ambient operating humidity: 5 to 90% noncondensing
- Software information: The software version of a product can be checked at https://unifi.ui.com
- UL 294 level: Destructive attack: Level I, Line security: Level I, Endurance: Level I, Standby power: Level I
- UL 294 statement: Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
- PoE cabling requirements: Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
- CAN/ULC-60839-11-1: Grade Grade assignment: I
- Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
UA-Pocket
Mechanical
- Mechanical Dimensions: 84 x 39 x 7.4 mm (3.3 x 1.5 x 0.3″)
- Weight: 16 g (0.56 oz)
- Enclosure material: Polycarbonate, stainless steel, silicone rubber
- Weatherproofing: IP54
Hardware
- NFC frequency: 13.56 MHz
- NFC technology: ISO/IEC 14443 Type A, MIFARE DESFire EV3 4K, UniFi Access Proprietary Security Protocol
- Ambient operating temperature: -10 to 45° C (14 to 113° F)
- Ambient operating humidity: 10 to 90% noncondensing
- Certification: CE
Produkte të afërt
UniFi Intercom Viewer UA-Intercom-Viewer-3 (3 PACK) – Monitor i Brendshëm për Intercom
512.33 €
Koha e arritjes së produktit : Qer 9, 2026 - Qer 16, 2026
UniFi Access Ultra UA-Ultra – Lexues për Kontroll të Qasjes
113.63 €
Koha e arritjes së produktit : Maj 27, 2026 - Maj 28, 2026
Access Reader G3 Black (UA-G3-B)
158.57 €
Koha e arritjes së produktit : Maj 27, 2026 - Maj 28, 2026
UniFi Access Reader G2 Professional (UA-G2-Pro)
464.84 €
Koha e arritjes së produktit : Maj 27, 2026 - Maj 28, 2026
